Cart
French English
 
 
 
 
 
 
  Categories
     Home     Informations     Catalog     Partners     Contact    My Account     
  Wind turbines
  Solar Modules
  Solar Systems
  Wind Solar Systems
  Charge Controllers
  Inverters
  Solar Batteries
  Solar Air Conditioner
  Hydro generator
  Solar Heating System
  System Monitoring & Meters
  Solar Hot Water
  Solar Lighting System
  Solar Pool System
  Wind Solar Lighting System
  Solar Pumping System
  Wind Pumping System
  Wind Solar pumping System
  Back Up System
  Energy Efficient Products
  Trackers
  Solar Accessories
    Communications
    Lightning Arrestor
    Mounting
    Active voltage level
    Cables
    Generator Starter
    Adjustable Desulphator
    Voltage Converter
    PowerTransfert
    Automatic transfert
    24 V From 12V Power source
    Combiner box
    12 V From 24V Power source
    Coffret FlexPowerOne
    Grounding
    DC Breakers
    MC Connector Cables
    Remote temp Sensor
    Solar Anti-Mostiquo
   
Low Active batteries charge
[LABL]
296 $CA

 

 

Available as Active High and Active Low

 

Basic Operation

Solar Converters Inc. Voltage Controlled Switch is a simple power relay switch which has user adjustable voltage setpoints. Normally the relay is not powered, connecting the common terminal (C) to the normally closed (NC) terminal.

The Active High unit monitors the incoming voltage and if it goes over the "high" setpoint for 3 seconds, the power relay will switch on, connecting the common terminal (C) to the normally open (NO) terminal.

Once the relay is on, the unit monitors the incoming voltage and if it goes below the "low" voltage setpoint for 3 seconds, the unit will turn off the power relay, connecting the common (C) terminal to the normally closed (NC).

Active Low operation is identical to the Active High listed above BUT the relay operation is opposite.

In Active Low operation, the unit monitors the incoming voltage and if it goes below the "low" setpoint for 3 seconds, the power relay will switch on, connecting the common terminal (C) to the normally open (NO) terminal.

Once the relay is on, the unit monitors the incoming voltage and if it goes above the high voltage setpoint for 3 seconds, the unit will turn off the power relay, connecting the common (C) terminal to the normally closed (NC).

·         Single unit 12, 18, 24, 36 and 48 V operation

·         Easy to setup, setpoints have a 1/10 th. scale factor. To set 12 V, set the setpoint to 1.2V

Electrical Specifications

 

Nominal Voltage (V)

12

18

24

36

48

Max Output (A)
Basically rating of 30 amp relay

30

30

30

15

03

Maximum Voltage (V)

63

       

Minimum Voltage (V)

10

       

Self Consumption

         

Quiescent (ma)

17

17

17

17

17

Relay on (ma)

75

57

47

37

32

Standard Delay on action is 3 seconds low, 1 second high
Delay of 0.1 sec to 45 Seconds are available. Please specify at time of ordering
Default relay position on startup between voltage setpoint - Relay Off

Mechanical Specifications

·         Weight:

o    0.3 lbs. approx., 1 lbs. approx with enclosure

·         Size:

o    4.125" x 2.8" x 2" open frame as shown above

·         Available in enclosure with 1/2" conduit knockouts

·         Connections:

o    Power:

o    Eurostyle Terminal Strip #6 AWG

·         Operating Temperature:

o    -40 to 60 deg. C

·         Humidity:

o    0 - 90 % non-condensing

 

 

 

 

Applications

·         Load Controller

·         Low Voltage Disconnect

·         Grid Intertie Controller

·         Wind/hydro Dump Controller

·         Generator Start Controller

·         Simple Charge Controller

·         Battery Vent Controller

·         Load Controller

·         Low Voltage Disconnect

·         Generator Start Controller

Features

·         Wide Voltage range

·         Fused and Transient protected

·         Adjustable high and low setpoints

·         High Reliability

 

Shipping:

 

RL 16 Battery 470 Ah 6 V
RL 16 Battery 470 Ah 6 V
562 $CA
548 $CA